( The values below are not guaranteed.)
| Test type | Unit | Standard | EMPV4-F |
|---|---|---|---|
| Thermal Conductivity | W/m・K | JIS R 2616 (Hot-wiremethod) | 1.5 |
| Thermal Conductivity | W/m・K | ISO22007-2 (Hot Disc method) | 1.3 |
| Color | - | - | Black |
| Thickness | mm | - | 1.0/1.5/2.0 / 2.5 / 3.0 / 3.5 |
| Specific Gravity | - | JIS Z 8807 | 3.55 |
| Hardness | ASKER C | JIS K 7312 | 40 |
| Hardness | Shore 00 | ASTM D 2240 | 70 |
| Tensile strength | MPa | JIS K 6251 | 0.51 |
| Elongation | % | JIS K 6251 | 16 |
| Volume Resistivity | Ω・cm | JIS K 6911 compliant | 1.0×1012 |
| Breakdown voltage | kV/mm | JIS C 2110-1 compliant | 6.0 |
| Withstanding voltage | kV/mm | JIS C 2110-1 compliant | 4.2 |
| Dielectric constant | 1MHz | Company standard | 12.7 |
| Loss tangent | 1MHz | Company standard | 0.13 |
| Flammability | - | UL94 | V-0 equivalent |
| Permeability (at 10MHz) | - | - | 13 |
| Operating temperature | ℃ | - | -40~110 |
| Available max.dimension※1 | mm | - | 210×510 |